Login
Anville 825 Datalogger
English Afrikaans Albanian Arabic Armenian Azerbaijani Basque Belarusian Bulgarian Catalan Chinese (Simplified) Chinese (Traditional) Croatian Czech Danish Dutch Estonian Filipino Finnish French Galician Georgian German Greek Haitian Creole Hebrew Hindi Hungarian Icelandic Indonesian Irish Italian Japanese Korean Latvian Lithuanian Macedonian Malay Maltese Norwegian Persian Polish Portuguese Romanian Russian Serbian Slovak Slovenian Spanish Swahili Swedish Thai Turkish Ukrainian Urdu Vietnamese Welsh Yiddish
Translate

traquelogo

Anville Instruments provide the various types of validation test sets for Hospital Sterilizer Validation, Washer Disinfector Validation, Pharmaceutical Autoclave Validation and Thermal Cycler Validation.

EaziVal Series 825 Test Set

This test set comprises of the following:

  • 1x Anville series 825 thermal validation interface
  • 1x Anville EaziVal SE software
  • 1x Ashcroft KXDHT pressure transducer
  • 16x Anville thermocouple sensors
  • 1x Anville thermocouple entry gland
  • 1x Anville series 275 temperature reference
  • 1x Anville series 300 temperature bath
  • 1x Ashcroft PDTG3089-CP916 calibrator
  • 1x Carry case

 

EaziVal Series 825 Thermal Cycler Test Set

This test set comprises of the following:

  • 1x Anville series 825 thermal validation interface
  • 1x Anville EaziVal SE software
  • 16x Anville thermal cycler sensors
  • 1x Anville series 275 temperature reference
  • 1x Techne FTE10DDC Thermo-regulator
  • 1x Techne 8 litre bath with cover

EaziVal is a Windows software package specially written to provide traceable validation of thermal processes and includes a site and machine database; thermocouple and pressure sensor calibration; data logging with trend displays and on-line reporting. The machine database, calibration results, test results and reports are stored in tamper-proof encrypted files.

EaziVal is designed for use with the Anville data loggers, it can be used immediately, no programming is required. No software license is required for installing EaziVal on your computers and copies can be downloaded free of charge from Anville website, allowing other computers to run EaziVal for additional report generation, test result archiving and analysis. 

 

Anville Series 825 Thermal Validation Interface

The Anville Series 825 TVI is designed for use with EaziVal SE software. Anville's thermal validation systems can be used wherever it is necessary to maintain a formal record to prove that the correct temperatures and pressures have been achieved during a critical process.

The Anville Series 825 TVI differs from the majority of data loggers by the design of the thermocouple input connection, associated thermocouple cold junction compensation and in the use of analogue input parallel processing enabling the unit to have a acquisition rate of better than once per second for all inputs. The Series 825 TVU uses individual high speed amplification and analogue to digital conversion on each input channel with conversion to engineering units (°C/°F) carried out by the internal microcontroller. Data is communicated to the computer in the correct engineering units enabling the system to have a traceable calibration certificate. The Series 825 TVI has an internal power supply to provide a 20VDC excitation voltage for the 4-20mA inputs and no separate power supply is required for a loop powered transducer.

In the Anville Series 825 TVI all cold junction compensation errors are minimised by using correctly compensated miniature type T thermocouple connectors with matching class 1 thermocouple wiring to the internal cold junction sensor. A 1/3 DIN PT100 sensor measures the cold junction temperature to an accuracy of ±0.1°C at 0°C. Design of the physical layout of the cold junction reduces any thermal scatter to a typical deviation of ±0.05°C.

The Anville Series 825 measurement range for type T thermocouples is -200°C to 300°C with a resolution of 0.01°C. Over a measurement range from -50°C to 300°C the overall system accuracy is ±0.25°C. This accuracy is maintained over an ambient operating temperature range from 0°C to 50°C and includes all errors due to thermocouple cold junction compensation, DC amplification, A/D conversion and thermocouple linearisation.

The Series 825 TVI accuracy of ±0.25°C is a worst case "out of the box" value including all system errors but excluding thermocouple sensor error.

Series 825 TVI Specifications

  • Type T Thermocouple inputs Channels 1-16
  • 4-20mA Channels PR1 & PR2
  • Type T thermocouple input Measurement range: -50.0°C to 300.0°C; Accuracy: +/- 0.25°C; Resolution: 0.01°C
  • Type T thermocouple input -50.0°C to 300.0°C: -200.0°C to -50.0°C; +/- 0.25°C: +/- 1.0°C; 0.01°C: 0.01°C
  • Transducer input -200.0°C to -50.0°C: 4-20mA; +/- 1.0°C: +/- 0.1%; 0.01°C: 1µA
  • Scanning speed All channels in less than 1 sec
  • Transducer power supply (internal) 20VDC
  • Operating ambient temperature 0°C to 50°C
  • Dimensions W x H x D 240mm x 140mm x 290mm
  • Weight  4kg

 

Series 275 Thermometer

For thermocouple sensor calibration of the complete EaziVal system the actual temperature of the calibration source must be accurately known. EaziVal provides multi-point calibration at "high", "low" and "check-point" temperatures with the scale and offset values automatically calculated for each sensor. Using a Series 275 digital thermometer as the UKAS calibrated temperature reference this information can be entered into EaziVal. The calibration results are then stored for reporting.

The Series 275 is a single channel, hand held temperature measuring system consisting of a high accuracy platinum resistance sensor coupled with a high accuracy digital thermometer. The combination of sensor and thermometer is calibrated by a UKAS accredited test house at five temperatures.

Digital thermometer Specifications

  • Range -199.00°C to 199.99°C Accuracy ±0.03°C
  • Range -200.0°C to 850.0°C Accuracy ±0.1°C
  • Resolution 0.01°C to 199.99°C then 0.1°C at 200°C and above
  • Dimensions 71mm wide x 142mm high x 26mm deep
  • Power supply 9V battery
  • Operating ambient 0°C to 40°C
  • PT100 sensor The 275 is supplied with a single 1/10 DIN 100O sensor in a stainless steel sheath 6mm diameter x 150mm length with 2m PTFE lead. Operating range: -80°C to 250°C.
  • UKAS calibration points 0°C, 100°C, 121°C, 134°C and 150°C, other points to special order.

 

Series 300 Temperature Calibrator

For thermocouple sensor calibration of the complete EaziVal system the temperature of the thermocouples must be maintained in a stable state. EaziVal provides multi-point calibration at 'high', 'low' and 'check-point' temperatures with the scale and offset values automatically calculated for each sensor. The Anville 300 bath has an operating range from 40°C to 325°C. The large sensor capacity of three 3mm, three 6mm and one 10mm diameter holes make the unit particularly suitable for thermocouple calibration.

Anville Series 300 Bath Specifications

  • Part number Anville 300
  • Temperature range 40°C to 325°C
  • Stability ±0.03°C
  • Block uniformity ±0.2°C
  • Accuracy ±0.3°C
  • Display resolution ±0.1°C
  • Set point resolution ±0.1°C
  • Measuring zone 0 to 50mm from base of well
  • Time to stability 10 minutes (after set temperature is reached
  • Heating time 9 minutes (from 40°C to 300°C)
  • Cooling time 18 minutes (from 300°C to 100°C)
  • Immersion tube 110mm deep
  • Fixed insert large sensor capacity of three 3mm, three 6mm and one 10mm diameter holes
  • Dimensions 203.2 x 203.2 x 222.25 mm deep
  • Power supply 230VAC/110VAC switchable
  • Weight 4.0kg
  • Operating ambient 10°C to 40°C
  • Supplied with two year warranty, fits sterilizer validation kit case or soft case available

 

Thermocouples

For sterilizer, washer-disinfector and thermal cycler validation we offer a range of thermocouples for use with the Series 825 TVI. Constructed using the best quality material for accurate and repeatable measurements the thermocouples are manufactured using class type T material in ptfe sheathing.

Sterilizer and washer-disinfector validation thermocouple

  • Part number 10B-T-CLASS1-5000-CAP-5A.
  • Temperature range -250°C to +250°C.
  • Accuracy ±0.5°C.
  • Material Class 1 type T ptfe sheathed.
  • Length 5m other lengths to order.
  • Connection Miniature thermocouple plug.

Thermal cycler validation thermocouple for 0.2ml wells

  • Part number 15A-T0.2-PTFE-1000-5A
  • Temperature range -50°C to +150°C.
  • Accuracy ±0.5°C.
  • Material Class 1 type T ptfe sheathed.
  • Length 1m, other lengths to special order.
  • Connection Miniature thermocouple plug.

Thermal cycler validation thermocouple for 0.5ml wells

  • Part number 15A-T0.5-PTFE-1000-5A
  • Temperature range -50°C to +150°C.
  • Accuracy ±0.5°C.
  • Material Class 1 type T ptfe sheathed.
  • Length 1m, other lengths to special order.
  • Connection Miniature thermocouple plug.

 

Ashcroft KXDHT pressure transducer

For sterilzer and washer-disinfector validation a standard pressure transducer is not adequate as the process temperature is frequently in excess of 80°C. The Ashcroft KXDHT tranducer is designed for continuous operation at process temperature up to 150°C and is much better suited for the purpose. It can be used directly connected to the machine with no cooling loop. Supplied with a fixed cable terminated with a plug suitable for the Series 825 TVI. Other plugs can also be supplied.

Ashcroft KXDHT Pressure Transducer Specifications

  • Part number KXDHT.
  • Pressure range -1 bar to 4 bar gauge.
  • Accuracy ±0.25%.
  • Span thermal drift ±0.03%/°C.
  • Repeatability 0.03% full scale
  • Median temperature range -30°C to 150°C.
  • Operating temperature range -30°C to 85°C.
  • Over pressure limit 10 bar.
  • Signal output 4-20mA.
  • Power supply 24VDC from Anville data logger.
  • Process connection G 1/4" male.
  • Process connection material Stainless steel 3 16Ti.
  • Connection 3m captive cable terminated with a plug to suit.


If you would like more information, please contact us to "Get On TRAQuE"

Partners

Anville Instruments
dekon
Ezidock
iwws
koslow
palamatic
Protak Scientific
Solo 2
temprecord
TPE
I2SL
rsc

Office Address

OfficeLocation

Our contact details in Singapore are:

TRAQuE Pte. Ltd.
51 Bukit Batok Crescent,
#08-25 Unity Centre
658077
Singapore
+65 6316 3885
+65 9735 1384
+65 6316 3885
www.traqueasia.com
traque-pte-ltd

Our mailing address in Malaysia is:

TRAQuE Sdn. Bhd.
Suite 13-10, Level 13,
Johor Bahru City Square Office Tower,
106 - 108, Jalan Wong Ah Fook,
80000 Johor Bahru.

If you would like further information on our products or services, then feel free to contact us using the form below. We look forward to working with you.

Contact Us

Please contact us if you would like further information on any of our products or services. We will get back to you as soon as possible.

Please use digits for your answer!

Latest News

TRAQuE Awarded bizSAFE Star

TRAQuE is pleased to announce we have been awarded BizSafe Star by the WSH Council.

 

Congratulations to the team and well done in the continued efforts in supporting safety.

 

TRAQuE Malaysia

We’ve always placed great importance on being close to our customers. The ability to provide local resources, respond quickly and be onsite as required has proven extremely valuable in the seven years since we began operations in Asia.

 

Protak Scientific Partnership
Protak Scientific Logo

We're delighted to be kicking off our partnership with Protak Scientific in Singapore. This revolutionary alternative to biological indicators for use when assessing VHP effectiveness is significantly quicker than current methods and can provide linear quantitative data, resulting in optimised cleaning processes and increased productivity.

We use cookies to personalise content, to provide social media features and to analyse our traffic. We may also share information about your use of our site with our social media, advertising and analytics partners who may combine it with other information that you’ve provided to them or that they’ve collected from your use of their services. You consent to our cookies if you continue to use our website.
Ok