English Afrikaans Albanian Arabic Armenian Azerbaijani Basque Belarusian Bulgarian Catalan Chinese (Simplified) Chinese (Traditional) Croatian Czech Danish Dutch Estonian Filipino Finnish French Galician Georgian German Greek Haitian Creole Hebrew Hindi Hungarian Icelandic Indonesian Irish Italian Japanese Korean Latvian Lithuanian Macedonian Malay Maltese Norwegian Persian Polish Portuguese Romanian Russian Serbian Slovak Slovenian Spanish Swahili Swedish Thai Turkish Ukrainian Urdu Vietnamese Welsh Yiddish
Translate

traquelogo

Scientific Datalogger

Calibrated and supplied with a traceable calibration certificate to ISO 17025 standards, the scientific datalogger records ensures integrity of critical products. With an accuracy of up to 0.2?C / 0.36?F and a display resolution of 0.01, and water proof to IP67, these loggers provide a robust but highly accurate solution for a multitude of high accuracy applciations.

32K Non-volatile Memory The Scientific recorder has a 32K memory allows 16 hours to 2 years of recording depending on sample rate. Optional Low Temperature Range With the optional stainless steel probes, select a low temperature thermistor sensor, which will allow temperature recording down to -80?C / -112?F.

Multiple Trip Recording
Use the Scientific recorder time and time again. After each use, download your data and the recorder is ready for its next application.
Long-life Lithium Battery
The Scientific range of recorders have a Lithium Thionyl Chloride battery, which gives an estimated 5 year battery life and is rated to temperatures down to -40?C / -40?F.
Calibrated to 0.2?C / 0.35?F
Scientific recorders go through a 3-point calibration process at time of manufacturing. All scientific recorders are supplied with a traceable ISO17025 accredited calibration certificates.
Four Probe Options Available
Choose from four different probe options: Stainless Steel straight or bent probe, Plastic Handle probe or the Teflon probe. More Details
LED Status Indicators
The entire Temprecord recorder range has out of range indication. Set parameters and a red or green LED flash every 10 seconds will tell the user at a glance whether or not data recording has remained within the limits set.

Push Button Start / Stop
This easy system allows you to start and stop your recorder anywhere without sophisticated software in the field. This feature can be enabled or disabled and then started and stopped within the Temprecord for Windows software.

Retaining Hole
Fully moulded and ultrasonically welded retaining hole for easy securing of the data logger within different environments

Specifications

Memory 32k non volatile
Sample Period Programmable between 2 seconds and 36 hours in 2 second increments
Start Delay Programmable between 2 seconds and 36 hours or use the start on date and time function
Start and Stop Start / Stop button on recorder or use the software and reader interface to start and stop recorder
Recording Duration 16 hours at 2 sec sample rate and 2 years with a 36 hours sample rate
Temperature Range
 Non Probe
 Standard Probe
 Low Temp Probe

-40?C / -40?F to +75?C / 167?F
-50?C / -58?F to +110?C / 230?F
-80?C / -112?F to +110?C / 230?F
Temperature Accuracy 0.2?C ~ 0.36?F over the range -20?C / -4?F to +50?C / 122?F otherwise 0.5?C / 0.9?F
Inside Range Indicator One flash from Green LED indicator every 10sec
Outside Range Indicator One flash from Red LED indicator every 10sec
Display Resolution 0.01?C ~ 0.01?F
Battery Type Primary Lithium Thionyl Chloride
Dimensions & Weight 129 x 73.5 x 14mm, 83 gms, Blue
5 1/8 x 2 7/8 x 5/8 inches, 2.92oz, Blue
Case Protection Rating Water proof to IP67 (NEMA 6)
Warranty Period 12 months on recorder from date of purchase ~ 2 years on battery


If you would like more information, please "Get On TRAQuE" and contact us.

Scientific
SKU Scientific_Dataloggers
Brand Temprecord

Temprecord Authorised Distributor

Office Address

 

OfficeLocation

Our contact details in Singapore are:

TRAQuE Pte. Ltd.
51 Bukit Batok Crescent,
#08-25 Unity Centre
658077
Singapore
+65 6316 3885
+65 6316 3885
www.traqueasia.com
traqueQRContact
traque-pte-ltd

Our mailing address in Malaysia is:

TRAQuE Sdn. Bhd.
Suite 13-10, Level 13,
Johor Bahru City Square Office Tower,
106 - 108, Jalan Wong Ah Fook,
80000 Johor Bahru.

If you would like further information on our products or services, then feel free to contact us using the form below. We look forward to working with you.

Contact Us
Please contact us if you would like further information on any of our products or services. We will get back to you as soon as possible.
Your Company Name
Please enter your name!
Please enter your email!
First Line of Your Address
Second Line of Your Address
Phone Number (inc Std Code)...
Write your message!
Form not working? Try contacting us using the QR Code: traqueQRContact

Latest News

TRAQuE Awarded bizSAFE Star

TRAQuE is pleased to announce we have been awarded BizSafe Star by the WSH Council.

 

Congratulations to the team and well done in the continued efforts in supporting safety.

 

TRAQuE Malaysia

We’ve always placed great importance on being close to our customers. The ability to provide local resources, respond quickly and be onsite as required has proven extremely valuable in the seven years since we began operations in Asia.

 

Protak Scientific Partnership
Protak Scientific Logo

We're delighted to be kicking off our partnership with Protak Scientific in Singapore. This revolutionary alternative to biological indicators for use when assessing VHP effectiveness is significantly quicker than current methods and can provide linear quantitative data, resulting in optimised cleaning processes and increased productivity.

We use cookies
Ok
We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.