Login
Temprecord Dataloggers
English Afrikaans Albanian Arabic Armenian Azerbaijani Basque Belarusian Bulgarian Catalan Chinese (Simplified) Chinese (Traditional) Croatian Czech Danish Dutch Estonian Filipino Finnish French Galician Georgian German Greek Haitian Creole Hebrew Hindi Hungarian Icelandic Indonesian Irish Italian Japanese Korean Latvian Lithuanian Macedonian Malay Maltese Norwegian Persian Polish Portuguese Romanian Russian Serbian Slovak Slovenian Spanish Swahili Swedish Thai Turkish Ukrainian Urdu Vietnamese Welsh Yiddish
Translate

traquelogo

Medical

Medical

SKU : Multitrip_Blue_-_Supercool

Multiple use logger for Medical shipment use. The Medical data loggers are fitted with long-life Lithium Thionyl Chloride (3.6V) batteries with a wide operating temperature range, allowing low-temperature recordings down to –50°C(-58°F). 

Accuracy & Traceability –Calibrated to 0.2°C / 0.35°F
The Medical data loggers go through a 3-Point calibration and correction process during manufacturing. The corrections are then applied to each data logger. Traceable Calibration Certificates are included with each logger from our ISO/IEC 17025 accredited laboratory. PDF copies of Calibrated Certificates are also available.

32K Non-volatile Memory
The medical Advanced Multi-Use data logger supports 32K of memory (32,511 samples). User-configurable sample periods provides from 16 hours up to 2 years of data recording.

Multi-Use Recorders
Use the Econolog recorder time and time again. After each use, download your data and the recorder is ready for its next application.
 

medical indicatorsLED Status Indicators
The entire Temprecord recorder range has out of range indication. Set parameters and a red or green LED flash every 10 seconds will tell the user at a glance whether or not data recording has remained within the limits set.

medical start stopPush Button Start / Stop
This easy system allows you to start and stop your recorder anywhere without sophisticated software in the field. This feature can be enabled or disabled and then started and stopped within the Temprecord for Windows software.

medical retaining holeRetaining Hole
Fully molded and ultrasonically welded retaining hole for easy securing of the data logger within different environments



If you would like more information, please contact us to "Get On TRAQuE"

Calibration Type

ISO 17025 Calibration

Model

Medical

Memory

32K Non-volatile

Sample Capacity

32,511 samples

Sample Period

Programmable between 2 second and 36 hours in 2 second increment

Start Delay

10s to 36 hrs

Start and Stop

Logger Button (if enabled), Palm PDA/Reader, TRW Software/Reader

Recording Duration

16hrs up to 2 years

Temperature Range

-50 ̊C to +60 ̊C (-58 ̊F to +140 ̊F)
With Probe: -50 ̊C to +60 ̊C (-58 ̊F to +140 ̊F)

Temperature Accuracy

With Probe: 0.2 ̊C over the range -40 ̊C to +50 ̊C (0.35 ̊F from -40 ̊F to +122 ̊F) else 0.5 ̊C (0.9 ̊F)
0.2 ̊C (0.35 ̊F) over the range -20 ̊C to +50 ̊C (-4 ̊F to +122 ̊F) else 0.5 ̊C (0.9 ̊F)

Display Resolution

0.01 ̊C (0.01 ̊F)

Within Limits Indicator

One flash from Green LED Indicator every 10 seconds

Out of Limits Indicator

One flash from Red LED Indicator every 10 seconds

Battery Type

Lithium Thionyl Chloride (3.6V)

Case Colour

Blue

Case Protection

IP67 or NEMA 6. Fully welded FDA approved food grade casing

Warranty Period

2 years on data logger from date of purchase 2 years on battery
Dimension (L x W x H) 0 x 0 x 0
Weight 0

You may also be interested in these products

Office Address

 

OfficeLocation

Our contact details in Singapore are:

TRAQuE Pte. Ltd.
51 Bukit Batok Crescent,
#08-25 Unity Centre
658077
Singapore
+65 6316 3885
+65 6316 3885
www.traqueasia.com
traqueQRContact
traque-pte-ltd

Our mailing address in Malaysia is:

TRAQuE Sdn. Bhd.
Suite 13-10, Level 13,
Johor Bahru City Square Office Tower,
106 - 108, Jalan Wong Ah Fook,
80000 Johor Bahru.

If you would like further information on our products or services, then feel free to contact us using the form below. We look forward to working with you.

Contact Us
Please contact us if you would like further information on any of our products or services. We will get back to you as soon as possible.
Your Company Name
Please enter your name!
Please enter your email!
First Line of Your Address
Second Line of Your Address
Phone Number (inc Std Code)...
Write your message!
Form not working? Try contacting us using the QR Code: traqueQRContact

Latest News

TRAQuE Awarded bizSAFE Star

TRAQuE is pleased to announce we have been awarded BizSafe Star by the WSH Council.

 

Congratulations to the team and well done in the continued efforts in supporting safety.

 

TRAQuE Malaysia

We’ve always placed great importance on being close to our customers. The ability to provide local resources, respond quickly and be onsite as required has proven extremely valuable in the seven years since we began operations in Asia.

 

Protak Scientific Partnership
Protak Scientific Logo

We're delighted to be kicking off our partnership with Protak Scientific in Singapore. This revolutionary alternative to biological indicators for use when assessing VHP effectiveness is significantly quicker than current methods and can provide linear quantitative data, resulting in optimised cleaning processes and increased productivity.